COMPANY HEADER
Request Information
CE Marked - Available Globally

Dymax® BlueWave® 200 version 3.1 is a high-intensity, light-curing spot-lamp system. This unit emits energy in the UVA and visible portion of the spectrum (300-450 nm) for light curing of adhesives, coatings, and encapsulants. Ideally suited for either manual or automated processes, the system contains an integral shutter which can be actuated by a foot pedal or PLC and a universal power input that provides consistent performance at any voltage. A wide range of light guides in various materials and configurations are available for use with this spot-curing unit, providing application flexibility.
Unit of Measure

Specifications

Brands

N/A BlueWave® Dymax®

Total Initial Intensities

N/A 280 to 450 nm40+ W/cm²

Visible Initial Intensities

N/A 400 to 450 nm17+ W/cm²
Ultraviolet A (UVA) Initial Intensities1 N/A 320 to 395 nm17+ W/cm²

UVB Initial Intensities

N/A 280 to 320 nm7 W/cm²

Intensity Adjustment

N/A Manual from 1 to 100 % Output

Power Supply

N/A Solid-state, 200 Watt

Bulb

N/A 200 Watt metal-halide bulb included Replacement in less than one minute

Reflector

N/A Elliptical; Glass with Dichroic Coating to Reflect Ultra Violet (UV) Minimize Infrared Radiation (IR)

Shutter Timer

N/A Digital LCD timer up to 9999.9 seconds Manual or timed shutter

Shutter Activation

N/A Foot Switch Programmable Logic Controller (PLC)

Input/Output (I/O) Port

N/A 15 Pin D - Sub-miniature Connector

Input Signals (Programmable Logic Controller (PLC) Integration)

N/A Lamp Control Programmable Logic Controller (PLC) Enable Shutter Activate Shutter Deactivate

Output Signals (Programmable Logic Controller (PLC) Integration)

N/A Bulb Life Expired Bulb Life Warning Lamp Status Lightguide Status Power Status Shutter Fault Shutter Status Temperature Fault Unit Status

Cooling

N/A Filtered fan arrangement; thermally controlled to maintain proper lamp temperature

Display

N/A 320 by 240 Pixels LCD Monochromatic

Weight

N/A 12.75 lb5.78 kg

Approval

N/A CE Marked

Warranty

N/A 1 Year from Purchase

Bulb Warranty

N/A Ignition warranted for 2000 hours

Type

N/A North American Version (Standard 120 Volt (V) Plug)

N/A Replacement Bulb - 38465

Power Requirements

Alternating Current (AC) Voltage

N/A 100 to 240 V

Frequency

N/A 50 to 60 Hz

Current

N/A 2.5 A

Overall Dimensions

Overall Width

N/A 12.5 in31.8 cm

Overall Depth

N/A 12 in30.5 cm

Overall Height

N/A 6.5 in16.5 cm

Accessories

N/A Item # 39560
ACCU-CAL™ 50 Radiometer for measuring the UV intensity of spot lamps, flood lamps, and conveyor systems

Item # 35284
UV-Blocking - Clear, Over-the-Glasses Eye Protection

Item # 35285
UV-Blocking - Tinted Dark, Over-the-Glasses Eye Protection

Item # 35286
UV-Blocking - Tint, Over-the-Glasses Eye Protection

Item # 39700
Lightguide Mounting Stand (fits 3 mm, 5 mm and 8 mm lightguides)

Liquid Lightguides available in 1, 2, 3, & 4 pole configurations

Item # 39029
3 mm/60º Angled Terminators for Lightguides

Item # 39030
3 mm/90º Angled Terminators for Lightguides

Item # 38042
5 mm/60º Angled Terminators for Lightguides

Item # 38049
5 mm/90º Angled Terminators for Lightguides

Item # 38968
Rod Lenses (BlueWave 200 with rod lens stand and clamp)

Item # 38699
2" x 2" Area (100 mW/cm²) Rod Lenses

Item # 38698
5" x 5" Area (30 mW/cm²) Rod Lenses

New 3.0 Design Includes

N/A

  • Updated front panel and large LCD display
  • Smooth, easy-to-clean front faceplate
  • Improved operator interface
  • Controlled warm-up sequence
  • Extended exposure timer setting to 9999.9 seconds
  • No light leakage from enclosure

Features

N/A

  • Patented intensity adjustment feature
  • Simple to operate and adjust
  • Integral shutter with digital timer
  • Proprietary "Cool Blue™" filter virtually eliminates liquid lightguide degradation
  • Easy-to-read, lighted front panel LCD display with enhanced unit status and notification displays
  • Improved user interface for easier operation
  • Extended exposure time settings to 9999.9 seconds
  • Manual intensity adjustment, >17000 mW/cm2 initial intensity
  • Up to 2000 hours useful bulb life
  • Foot switch or PLC integration
  • Wide range of lightguides available (liquid/fiber, single/multi-pole, various lengths)
  • Controlled power-up sequence ensures proper temperature
  • Smooth front panel surface that is easier to clean
  • Fast bulb replacement

Additional Information

N/A The faceplate design of the BlueWave® 200 V3.1 has an operator interface with an easy-to-read LCD display and patented intensity adjustment control. The control is important for validating an appropriate intensity range and maintaining that range during production. Intensity measurement is easily accomplished with the Dymax® ACCU-CAL™ 50 radiometer. Scheduled intensity measurements taken during the production process will indicate whether additional intensity adjustments are required. This method of measurement provides the most accurate readings as they are taken through the lightguide in the actual production setting.

  • 1 As measured with a Dymax ACCU-CAL™ 50 Radiometer (320 to 395 nm) and lightguide simulator. Excessive on/off cycles and improper cooling may affect bulb degradation and therefore no warranty is expressed or implied.