Items |
![]() 1120-M-UR MD® 300 Centipoises (CP) Nominal Viscosity In-Vitro Diagnostic Adhesive |
![]() 1072-M MD® 1,000 Centipoises (CP) Nominal Viscosity In-Vitro Diagnostic Adhesive |
![]() 1187-M MD® 450 Centipoises (CP) Nominal Viscosity In-Vitro Diagnostic Adhesive |
![]() 1201-M-GEL-SC MD® 38,000 Centipoises (CP) Nominal Viscosity In-Vitro Diagnostic Adhesive |
![]() 1201-M-SC MD® 600 Centipoises (CP) Nominal Viscosity In-Vitro Diagnostic Adhesive |
|||||
Description |
N/A
UV/LED light-curable adhesives bond glass and other difficult substrates such as COC/COP thermoplastics used for in-vitro diagnostics applications. Rapid assembly of microplates, lab-on-chip devices, and silicon wafers used in blood and tissue testing is possible with fast light curing, one-component formulations that require no mixing. Products with Dymax® Ecnompass® or patented See-Cure and Ultra-Red® fluorescing technologies are available.
|
|||||||||
Brands | N/A Dymax® MD® | |||||||||
Nominal Viscosity | N/A 300 cP | N/A 1,000 cP | N/A 450 cP | N/A 38,000 cP | N/A 600 cP | |||||
Cured Elongation at Break | N/A | N/A | N/A | N/A 170 % | N/A | |||||
Recommended Substrates | N/A Acrylonitrile Butadiene Styrene (ABS) Polycarbonate (PC) Polyimide (PA) Polystyrene (PS) Polyurethane (PU) Polyvinyl chloride (PVC) | N/A Cyclo Olefin Copolymer (COC) Cyclo Olefin Polymer (COP) Polystyrene (PS) Polyurethane (PU) Polyvinyl chloride (PVC) Stainless Steel (SS) | N/A Acrylonitrile Butadiene Styrene (ABS) Polycarbonate (PC) Polyethylene Terephthalate (PET) Polyvinyl chloride (PVC) | N/A Acrylonitrile Butadiene Styrene (ABS) Polycarbonate (PC) Polyether Block Amide (PEBA) Polyethylene Terephthalate (PETL) Polyurethane (PU) Polyvinyl chloride (PVC) | N/A Acrylonitrile Butadiene Styrene (ABS) Polycarbonate (PC) Polyether Block Amide (PEBA) Polyethylene Terephthalate (PET) Polyurethane (PU) Polyvinyl chloride (PVC) | |||||
Rheology | N/A Newtonian | N/A Newtonian | N/A Newtonian | N/A | N/A Newtonian | |||||
Durometer Hardness | N/A D70 | N/A A58 | N/A D60 | N/A D50 | N/A D60 | |||||
Tensile at Break | N/A 19 MPa2,800 psi | N/A 4.8 MPa700 psi | N/A 19.9 MPa2,900 psi | N/A | N/A 14 MPa2,000 psi | |||||
Elongation at Break | N/A 30 % | N/A 700 % | N/A 200 % | N/A | N/A 170 % | |||||
Modulus of Elasticity | N/A 158 MPa23,000 psi | N/A 3.4 MPa500 psi | N/A 158 MPa23,000 psi | N/A | N/A 120 MPa17,000 psi | |||||
Fluorescing1 | N/A Ultra-Red® | N/A No | N/A Blue | N/A | N/A No | |||||
Recommended Adhesives | N/A Acrylonitrile-Butadiene-Styrene (ABS) Cellulose Acetate Propionate (CAP) Polyamide (PA) Polycarbonate (PC) Polystyrene (PS) Polyurethane (PU) Polyvinyl Chloride (PVC) Styrene-Acrylonitrile (SAN) | N/A Acrylonitrile-Butadiene-Styrene (ABS) Borosilicate Glass (GL), Quartz Glass (GL), and Mica Glass (GL) Cyclo Olefin Polymer/Copolymer: (COP) Poly Methyl Methacrylate (PMMA) Polyamide (PA) Polycarbonate (PC) Polyether Block Amide (PEBA) Polyetherimide (PEI) Polyethylene Terephthalate (PET) Polyethylene Terephthalate Glycol (PETG) Polyimide (PI) Polystyrene (PS) Polysulfone (PSU) Polyurethane (PU) Polyvinyl Chloride (PVC) Stainless Steel (SS) Styrene-Acrylonitrile (SAN) Thermoplastic Polyurethane (TPU) | N/A Acrylonitrile-Butadiene-Styrene (ABS) Cellulose Acetate Propionate (CAP) Polycarbonate (PC) Polyethylene Terephthalate (PET) Polyethylene Terephthalate Glycol (PETG) Polyvinyl Chloride (PVC) | N/A | N/A Acrylonitrile-Butadiene-Styrene (ABS) Polyamide (PA) Polycarbonate (PC) Polyether Block Amide (PEBA) Polyethylene Terephthalate (PET) Polyurethane (PU) | |||||
Limited Applications | N/A | N/A Polyetherimide (PEI) | N/A | N/A | N/A Poly (Methyl Methacrylate (PMMA)) | |||||
Industry Standards | N/A | N/A | N/A | N/A International Organization for Standardization (ISO 10993) | N/A | |||||
Industries Served | N/A Medical | N/A Medical | N/A Medical | N/A | N/A Medical | |||||
Features | N/A | N/A | N/A |
N/A
|
N/A | |||||
Additional Information |
N/A
Dymax® MD® Adhesives, specially formulated for disposable medical device assembly, are used in a wide range of applications including catheter, syringe, anesthesia mask, reservoir, tube set, and medical electronics assembly. They help optimize assembly speeds to enable faster processing, greater output, and lower processing costs while allowing for 100% in-line inspection of bond lines. All of our adhesives are no solvents added, and meet both USP Class VI and ISO 10993 biocompatibility standards. MD® adhesives are intended for use in short-term (<29 days) or single-use disposable-device applications only. Dymax® does not authorize their use in long-term implant applications. In all cases, it's the user's responsibility to determine and validate the suitability of these adhesives in the intended medical device. Compatible sterilization methods include gamma irradiation and ethylene oxide. Sterilization by autoclaving may be limited to certain applications. It remains the user's obligation to ascertain the effect of sterilization on the cured adhesive. |
N/A
Dymax® MD® Adhesives, specially formulated for disposable medical device assembly, are used in a wide range of applications including catheter, syringe, anesthesia mask, reservoir, tube set, and medical electronics assembly. They help optimize assembly speeds to enable faster processing, greater output, and lower processing costs while allowing for 100% in-line inspection of bond lines. All of our adhesives are no solvents added, and meet both USP Class VI and ISO 10993 biocompatibility standards. MD® adhesives are intended for use in short-term (<29 days) or single-use disposable-device applications only. Dymax® does not authorize their use in long-term implant applications. In all cases, it's the user's responsibility to determine and validate the suitability of these adhesives in the intended medical device. Compatible sterilization methods include gamma irradiation and ethylene oxide. Sterilization by autoclaving may be limited to certain applications. It remains the user's obligation to ascertain the effect of sterilization on the cured adhesive. |
N/A
Dymax® MD® Adhesives, specially formulated for disposable medical device assembly, are used in a wide range of applications including catheter, syringe, anesthesia mask, reservoir, tube set, and medical electronics assembly. They help optimize assembly speeds to enable faster processing, greater output, and lower processing costs while allowing for 100% in-line inspection of bond lines. All of our adhesives are no solvents added, and meet both USP Class VI and ISO 10993 biocompatibility standards. MD® adhesives are intended for use in short-term (<29 days) or single-use disposable-device applications only. Dymax® does not authorize their use in long-term implant applications. In all cases, it's the user's responsibility to determine and validate the suitability of these adhesives in the intended medical device. Compatible sterilization methods include gamma irradiation and ethylene oxide. Sterilization by autoclaving may be limited to certain applications. It remains the user's obligation to ascertain the effect of sterilization on the cured adhesive. |
N/A
Flexible, High-Viscosity Multipurpose Medical Adhesive for Plastics Assembly MD® 1201-M-GEL-SC medical device adhesive rapidly bonds a variety of flexible and rigid plastics typically used in the manufacture of medical devices. This product features Dymax®'s® patented See-Cure technology for easy visual confirmation of material placement and verification of full cure. Bondable substrates include PC, PVC, PU, ABS, and PET as well as PEBA. Applications include the assembly of reservoirs, catheters, tube sets, and fittings. 1201-M-GEL-SC also meets a variety of ISO 10993 biocompatibility approvals. MD® Medical Device adhesives have no solvents added and cure upon exposure to light. Their ability to cure in seconds enables faster processing, greater output, and lower processing costs. When cured with Dymax® light-curing spot lamps, focused beam lamps, flood lamps, or conveyor systems they deliver optimum speed and performance for medical device assembly. lamps offer the optimum balance of UV and visible light for the fastest, deepest cures. MD® 1201-M-GEL-SC medical device adhesive is in full compliance. |
N/A
Dymax® MD® Adhesives, specially formulated for disposable medical device assembly, are used in a wide range of applications including catheter, syringe, anesthesia mask, reservoir, tube set, and medical electronics assembly. They help optimize assembly speeds to enable faster processing, greater output, and lower processing costs while allowing for 100% in-line inspection of bond lines. All of our adhesives are no solvents added, and meet both USP Class VI and ISO 10993 biocompatibility standards. MD® adhesives are intended for use in short-term (<29 days) or single-use disposable-device applications only. Dymax® does not authorize their use in long-term implant applications. In all cases, it's the user's responsibility to determine and validate the suitability of these adhesives in the intended medical device. Compatible sterilization methods include gamma irradiation and ethylene oxide. Sterilization by autoclaving may be limited to certain applications. It remains the user's obligation to ascertain the effect of sterilization on the cured adhesive. |
|||||
Note |
N/A
Ultra-Red® (Patented Fluorescing Technology) (UR) Individual Product Data Sheets (PDS) list complete test data, with copies of test reports available upon request. |
N/A Individual Product Data Sheets (PDS) list complete test data, with copies of test reports available upon request. | N/A Individual Product Data Sheets (PDS) list complete test data, with copies of test reports available upon request. | N/A |
N/A
See-Cure (Patented Color-Change Technology) Individual Product Data Sheets (PDS) list complete test data, with copies of test reports available upon request. |
|||||
|