Brands |
N/A Dymax® MD® |
Nominal Viscosity |
N/A 1,100 cP |
Cured Durometer Hardness |
N/A A70 |
Cured Elongation at Break |
N/A 600 % |
Recommended Substrates |
N/A Acrylonitrile Butadiene Styrene (ABS) Cyclo Olefin Copolymer (COC) Cyclo Olefin Polymer (COP) Polycarbonate (PC) Polymethyl methacrylate (PMMA) Polyvinyl chloride (PVC) |
Biocompatibility |
N/A ISO 10993-5 Cytotoxicity |
Recommended Adhesives |
N/A Acrylonitrile-Butadiene-Styrene (ABS) Aluminum (AL) Ceramic (CER) Cyclo Olefin Copolymer (COC) Cyclo Olefin Polymer (COP) Eva Ethylene-Vinyl Acetate (EVA) Glass: Borosillicate, Quartz, and Mica (Limited Applications) Polyamide (PA) Polycarbonate (PC) Polycyclohexylene Dimethylene (PCTG) Polyether Block Amide (PEBA) Polyetherimide (PEI) Polyethylene Terephthalate (PET) Polyethylene Terephthalate Glycol (PETG) Polyimide (PI) (Limited Applications) Polymethyl Methacrylate (PMMA) Polystyrene (PS) Polysulfone (PSU) Polyurethane (PU) (Limited Applications) Polyvinyl Chloride (PVC) Stainless Steel (SS) Styrene-Acrylonitrile (SAN) Terephthalateglycol Thermoplastic Polyurethane (TPU) |
Solvent Content |
N/A No Nonreactive Solvents |
Chemical Class |
N/A Acrylated Urethane |
Uncured Appearance |
N/A Colorless Translucent Liquid |
Soluble in |
N/A Organic Solvents |
Density |
N/A 1.01 g/ml |
Test Method for Density |
N/A American Society for Testing and Materials (ASTM D1875) |
Test Method for Nominal Viscosity |
N/A Dymax® Standard Test Method (DSTM 502) |
Shelf Life at 1 to 5 Degree Celsius (ºC) Temperature from Date of Manufacture |
N/A 12 months |
Test Method for Durometer Hardness |
N/A American Society for Testing and Materials (ASTM D2240) |
Test Method for Tensile at Break |
N/A American Society for Testing and Materials (ASTM D638) |
Elongation at Break |
N/A 600 % |
Test Method for Elongation at Break |
N/A American Society for Testing and Materials (ASTM D638) |
Test Method for Modulus of Elasticity |
N/A American Society for Testing and Materials (ASTM D638) |
Durometer Hardness |
N/A A70 |
Refractive Index at 20 Degree Celsius (ºC) Temperature |
N/A 1.49 |
Test Method for Refractive Index at 20 Degree Celsius (ºC) Temperature |
N/A American Society for Testing and Materials (ASTM D542) |
Boiling Water Absorption (2 Hours (h)) |
N/A 1.5 % |
Test Method for Boiling Water Absorption (2 Hours (h)) |
N/A American Society for Testing and Materials (ASTM D570) |
Water Absorption (25 Degree Celsius (ºC) Temperature, 24 Hours (h)) |
N/A 1.0 % |
Test Method for Water Absorption (25 Degree Celsius (ºC) Temperature, 24 Hours (h)) |
N/A American Society for Testing and Materials (ASTM D570) |
Linear Shrinkage |
N/A 2.3 % |
Test Method for Linear Shrinkage |
N/A American Society for Testing and Materials (ASTM D2566) |
Glass Transition (Tg) |
N/A 57 ºC |
Test Method for Glass Transition (Tg) |
N/A American Society for Testing and Materials (ASTM D5418) |
Features |
N/A
|
Additional Information |
N/A
Flexible Plastics Adhesive with Ultra-Red® Fluorescing Technology Dymax® MD® 1172-M-UR medical device adhesive is designed for rapid bonding of COC, COP, and a variety of other plastics typically used in the manufacture of medical devices. Applications include in vitro diagnostics, reservoir assembly, transducer assembly, and medical potting. 1172-M-UR fluoresces bright red under low-intensity black light (365 nm). The bright red fluorescence contrasts extremely well on plastics that naturally fluoresce blue in color (like PVC), and greatly assists with visual inspection of bond-line area. This flexible, Ultra-Red® fluorescing product bonds a wide variety of substrates including COC, COP, ABS, PC, PMMA, PVC, EVA, PA, PCTG, PEBA, PEI, PET, PETG, PS, PSU, SAN, TPU, CER, AL, and Stainless Steel. Dymax® MD® medical device adhesives have no solvents added and cure upon exposure to light. Their ability to cure in seconds enables faster processing, greater output, and lower processing costs. When cured with Dymax® light-curing spot lamps, focused beam lamps, flood lamps, or conveyor systems they deliver optimum speed and performance for medical device assembly. Dymax® lamps offer the optimum balance of UV and visible light for the fastest, deepest cures. MD® 1172-M-UR medical device adhesive is in full compliance
|
N/A
Spot Lamp |