Consistent curing requires periodic monitoring of visible energy intensity or dose. The ACCU-CAL™ 50V radiometer is simple to operate and offers repeatable measurement of visible light. The ACCU-CAL™ 50V can measure visible light energy emitted from lightguides (3 mm, 5 mm, and 8 mm), flood systems, and conveyors. With a spectral sensitivity from 400 to 470 nm (blue portion of the visible spectrum), the ACCU-CAL™ 50V measures intensities from 1 mW/cm2 to 40 W/cm2. A specially designed photo sensor assembly protects the photo-sensor from the high temperatures sometimes associated with today's high-intensity spot lamps.

Complete radiometer (without lightguide adapters or lightguide simulator (A lightguide simulator is used to measure direct spot lamp intensity (required to calculate lightguide transmission)); includes storage/carrying case.
Unit of Measure

Specifications

Brands

N/A ACCU-CAL™ Dymax®

Spectral Sensitivity

N/A 400 to 470 nm

Intensity Range

N/A 1 mW/cm² to 40 W/cm²

Calibration Period

N/A 12 months

Light Sources Application

N/A Conveyors Floods
Battery Life1 N/A 250 h

Approval

N/A CE Marked

Resolution

Intensity2 N/A 1 mW/cm²

Dose

N/A 1 mJ/cm²

Operating Temperature Ranges

Optometer Operating Temperature Ranges

N/A + 5 to + 40 ºC

Continuous Detector Operating Temperature Ranges

N/A 120 ºC

Continuous Peak Operating Temperature Ranges

N/A 200 ºC

Measurement Modes

Intensity Measurement Modes

N/A mW/cm² W/cm²

Peak Intensity Measurement Modes

N/A mW/cm² W/cm²

Dose Measurement Modes

N/A J/cm²

Power Supply

Number of Battery

N/A 2

Battery Type

N/A AA

Sensor Dimensions

Photo-Sensor Diameter

N/A 9 mm

Diameter

N/A 37 mm

Thickness

N/A 8 mm

Cable Length

N/A 1 m

Meter Dimensions

Meter Length

N/A 120 mm

Meter Width

N/A 65 mm

Meter Thickness

N/A 23 mm

Dymax® ACCU-CAL™ Radiometers

N/A Dymax® offers ACCU-CAL™ radiometers for spots, floods, and conveyors. Kits for spot lamps include the complete radiometer with 3, 5, and 8 mm lightguide adapters and a lightguide simulator. Adapter kits are available separately for users who have an existing flood/conveyor kit and need to use it for spot systems. All radiometer kits include a storage/carrying case. ACCU-CAL™ radiometers are calibrated to measure either UV-A (320 to 390 nm), LED (~ 350 to 450 nm), or visible (395 nm to 465 nm) light intensity.

Radiometer Calibration

N/A Dymax® recommends recalibrating the ACCU-CAL™ 50V radiometer annually to ensure proper operation of the instrument. Calibration services are available through Dymax®.

Features

N/A

  • Simple to Operate
  • Can be Used to Test Spot or Flood Lamps, as Well as Conveyor Systems
  • Set Screw Locks Lightguide in Place
  • PTB and NIST Traceable

Three Reasons to Use a Visible Radiometer

N/A

  • Maintaining a Light-Curing Process - A radiometer measures whether a light-curing system is providing intensity above the "bulb change" intensity. Radiometers provide the same monitoring control for light-curing processes that thermometers provide for thermal processes.
  • Providing a Worker Friendly Light-Curing Process - The ACCU-CAL™ 50 is sufficiently sensitive to measure the intensity of stray or reflected visible light (as little as 1 mW/cm2).
  • Measuring Transmission Rates Through Substrates - A radiometer can be used to measure the transmission rates of various wavelengths through substrates that absorb UV and/or visible light. To assure an effective curing process it is critical to measure the light intensity reaching the resin below the intervening substrate.

  • 1 Automatic Shutoff After 1 Hour
  • 2 To Three Significant Digits