COMPANY HEADER
Needle bonding adhesives cure in seconds when exposed to UV/Visible/LED light for high-speed, high-volume syringe assembly lines that incorporate inline testing and packaging. Medica- grade products feature red or blue fluorescing for quality inspection under automated sensing or vision systems. Bondable substrates include PC, PMMA, and PA plastics as well as glass and metal.

  • UV/Visible/LED light curable
  • Single component materials require no mixing
  • Meet a variety of ISO 10993 standards
  • LED-curable materials available
  • Compatible with gamma, EtO, and E-Beam sterilization
  • Fluorescing for automated inspection
Request Information
Unit of Measure
Items
MD® Needle Bonding Adhesives

MD® 284 Megapascal (MPa) Modulus of Elasticity Needle Bonding Adhesive

MD® Needle Bonding Adhesives

MD® 359 Megapascal (MPa) Modulus of Elasticity Needle Bonding Adhesive

MD® Needle Bonding Adhesives

MD® 367 Megapascal (MPa) Modulus of Elasticity Needle Bonding Adhesive

MD® Needle Bonding Adhesives

MD® 447 Megapascal (MPa) Modulus of Elasticity Needle Bonding Adhesive

MD® Needle Bonding Adhesives

MD® 397 Megapascal (MPa) Modulus of Elasticity Needle Bonding Adhesive
Description N/A Needle bonding adhesives cure in seconds when exposed to UV/Visible/LED light for high-speed, high-volume syringe assembly lines that incorporate inline testing and packaging. Medica- grade products feature red or blue fluorescing for quality inspection under automated sensing or vision systems. Bondable substrates include PC, PMMA, and PA plastics as well as glass and metal.

  • UV/Visible/LED light curable
  • Single component materials require no mixing
  • Meet a variety of ISO 10993 standards
  • LED-curable materials available
  • Compatible with gamma, EtO, and E-Beam sterilization
  • Fluorescing for automated inspection
Brands N/A Dymax® MD®
Recommended Substrates N/A Polycarbonate (PC) Polystyrene (PS) Stainless Steel (SS) N/A Polycarbonate (PC) Polystyrene (PS) Stainless Steel (SS) N/A Polycarbonate (PC) Polystyrene (PS) Stainless Steel (SS) N/A Polycarbonate (PC) Polystyrene (PS) Stainless Steel (SS) N/A Acrylonitrile Butadiene Styrene (ABS) Polycarbonate (PC) Polymethyl methacrylate (PMMA) Stainless Steel (SS)
Nominal Viscosity N/A 2,800 cP N/A 150 cP N/A 450 cP N/A 6,000 cP N/A 150 cP
Rheology N/A Thixotropic N/A Newtonian N/A Newtonian N/A Thixotropic N/A Newtonian
Cured Durometer Hardness N/A D70 N/A D70 N/A D57 N/A D65 N/A D70
Tensile at Break N/A 22 MPa3,300 psi N/A 21 MPa3,200 psi N/A 17 MPa2,500 psi N/A 23 MPa3,400 psi N/A 18.6 MPa2,700 psi
Elongation at Break N/A 200 % N/A 160 % N/A 80 % N/A 150 % N/A 150 %
Modulus of Elasticity N/A 284 MPa41,300 psi N/A 359 MPa52,170 psi N/A 367 MPa56,300 psi N/A 447 MPa65,000 psi N/A 397 MPa57,600 psi
Fluorescing1 N/A Ultra-Red® N/A Blue N/A Blue N/A Ultra-Red® N/A Ultra-Red®
Recommended Adhesives N/A Acrylonitrile-Butadiene-Styrene (ABS) Borosilicate Glass (GL), Quartz Glass (GL), and Mica Glass (GL) Poly Methyl Methacrylate (PMMA) Polyamide (Nylon 6/6) (PA) Polycarbonate (PC) Stainless Steel (SS) N/A Acrylonitrile-Butadiene-Styrene (ABS) Poly Methyl Methacrylate (PMMA) Polyamide (Nylon 6/6) (PA) Polycarbonate (PC) Stainless Steel (SS) N/A Acrylonitrile-Butadiene-Styrene (ABS) Poly Methyl Methacrylate (PMMA) Polyamide (Nylon 6/6) (PA) Polycarbonate (PC) Stainless Steel (SS) N/A Acrylonitrile-Butadiene-Styrene (ABS) Poly Methyl Methacrylate (PMMA) Polyamide (Nylon 6/6) (PA) Polycarbonate (PC) Stainless Steel (SS) N/A Acrylonitrile-Butadiene-Styrene (ABS) Poly Methyl Methacrylate (PMMA) Polycarbonate (PC) Stainless Steel (SS)
Substrate Bonding2 N/A Polypropylene (PP)
Uncured Appearance N/A
Cured Elongation at Break N/A
Features N/A
Additional Information N/A Dymax® MD® Adhesives, specially formulated for disposable medical device assembly, are used in a wide range of applications including catheter, syringe, anesthesia mask, reservoir, tube set, and medical electronics assembly. They help optimize assembly speeds to enable faster processing, greater output, and lower processing costs while allowing for 100% in-line inspection of bond lines. All of our adhesives are no solvents added and meet both USP Class VI and ISO 10993 biocompatibility standards.

MD® adhesives are intended for use in short-term (<29 days) or single-use disposable-device applications only. Dymax® does not authorize their use in long-term implant applications. In all cases, it's the user's responsibility to determine and validate the suitability of these adhesives in the intended medical device.

Compatible sterilization methods include gamma irradiation and ethylene oxide. Sterilization by autoclaving may be limited to certain applications. It remains the user's obligation to ascertain the effect of sterilization on the cured adhesive.
Note N/A Ultra-Red® (Patented Fluorescing Technology) (UR)

Individual Product Data Sheets (PDS) list complete test data, with copies of test reports available upon request.
N/A Individual Product Data Sheets (PDS) list complete test data, with copies of test reports available upon request. N/A Individual Product Data Sheets (PDS) list complete test data, with copies of test reports available upon request. N/A Ultra-Red® (Patented Fluorescing Technology) (UR)

Individual Product Data Sheets (PDS) list complete test data, with copies of test reports available upon request.
N/A Ultra-Red® (Patented Fluorescing Technology) (UR)

See-Cure (Patented Color-Change Technology)

Individual Product Data Sheets (PDS) list complete test data, with copies of test reports available upon request.
  • 1 U.S. Patents 6,080,450 & 7,892,386.
  • 2 Requires Surface Treatment (e.g., Plasma, Corona Treatment, Etc.)