Items |
![]() 1121-M MD® Series 450 Centipoise (cP) Nominal Viscosity Medical Device Adhesive |
![]() 1128A-M MD® Series 600 Centipoise (cP) Nominal Viscosity Medical Device Adhesive |
![]() 1161-M MD® Series 300 Centipoise (cP) Nominal Viscosity Medical Device Adhesive |
![]() 1204-M-SC MD® Series 12,000 Centipoise (cP) Nominal Viscosity Medical Device Adhesive |
![]() 1209-M-UR-SC MD® Series 12,00 Centipoise (cP) Nominal Viscosity Medical Device Adhesive |
|||||
Description |
N/A
Multipurpose medical device adhesives are designed to rapidly bond medical-grade plastics upon exposure to UV/Visible light. The products meet ISO approvals and bond well to many different substrates including tinted and UV-inhibited plastics. Some formulations feature patented Encompass® technology which enables easy visual confirmation of adhesive placement and cure and fluorescence for post-cure quality inspection.
|
|||||||||
Brands | N/A Dymax® MD® | |||||||||
Nominal Viscosity | N/A 450 cP | N/A 600 cP | N/A 300 cP | N/A 12,000 cP | N/A 1,200 cP | |||||
Rheology | N/A Newtonian | |||||||||
Cured Durometer Hardness | N/A D65 | N/A D80 | N/A D70 | N/A A60 | N/A D60 | |||||
Tensile at Break | N/A 15.8 MPa2,300 psi | N/A 30 MPa4,300 psi | N/A 17 MPa2,500 psi | N/A 6.9 MPa1,000 psi | N/A 15.6 MPa2,275 psi | |||||
Cured Elongation at Break | N/A 225 % | N/A 13 % | N/A 120 % | N/A 380 % | N/A 770 % | |||||
Modulus of Elasticity | N/A 175.8 MPa25,500 psi | N/A 640 MPa93,000 psi | N/A 300 MPa44,000 psi | N/A 5.1 MPa740 psi | N/A 641 MPa93,000 psi | |||||
Fluorescing1 | N/A Blue | N/A Blue | N/A Blue | N/A No | N/A Ultra-Red® | |||||
Industries Served | N/A Medical | |||||||||
Recommended Adhesives | N/A Acrylonitrile-Butadiene-Styrene (ABS) Poly Methyl Methacrylate (PMMA) Polycarbonate (PC) Polyethylene Terephthalate Glycol (PETG) Polystyrene (PS) Polyurethane (PU) Polyvinyl Chloride (PVC) | N/A Acrylonitrile-Butadiene-Styrene (ABS) Borosilicate Glass (GL), Quartz Glass (GL), and Mica Glass (GL) Polyamide (PA) Polyether Block Amide (PEBA) Polyetherimide (PEI) Polystyrene (PS) Polyurethane (PU) Styrene-Acrylonitrile (SAN) | N/A Acrylonitrile-Butadiene-Styrene (ABS) Borosilicate Glass (GL), Quartz Glass (GL), and Mica Glass (GL) Cellulose Acetate Propionate (CAP) Poly Methyl Methacrylate (PMMA) Polycarbonate (PC) Polyetherimide (PEI) Polystyrene (PS) Stainless Steel (SS) Styrene-Acrylonitrile (SAN) | N/A Acrylonitrile-Butadiene-Styrene (ABS) Polycarbonate (PC) Polyetherimide (PEI) Polyurethane (PU) Polyvinyl Chloride (PVC) Thermoplastic Polyurethane (TPU) | N/A Acrylonitrile-Butadiene-Styrene (ABS) Polycarbonate (PC) Polyethylene Terephthalate Glycol (PETG) Polystyrene (PS) Polyvinyl Chloride (PVC) Styrene-Acrylonitrile (SAN) Thermoplastic Polyurethane (TPU) | |||||
Recommended Substrates | N/A Acrylonitrile Butadiene Styrene (ABS) Polycarbonate (PC) Polyurethane (PU) Polyvinyl chloride (PVC) | N/A Acrylonitrile Butadiene Styrene (ABS) Aluminum (AL) Glass (GL) Nickel Titanium (NiTi) Polyimide (PA) Polyurethane (PU) Stainless Steel (SS) | N/A Acrylonitrile Butadiene Styrene (ABS) Polycarbonate (PC) Polymethyl methacrylate (PMMA) Polyvinyl chloride (PVC) Stainless Steel (SS) | N/A Acrylonitrile Butadiene Styrene (ABS) Ethylene Vinyl Acetate (EVA) Polycarbonate (PC) Polyurethane (PU) Polyvinyl chloride (PVC) | N/A Acrylonitrile Butadiene Styrene (ABS) Polycarbonate (PC) Polystyrene (PS) Polyvinyl chloride (PVC) Styrene Ethylene Butylene Styrene (SEBS) | |||||
Industry Standards | N/A | |||||||||
Limited Applications | N/A Polyetheretherketone (PEEK) Polyetherimide (PEI) Polyethylene Terephthalate (PET) | N/A Polysulfone (PSU) | N/A Polyamide (PA) Polyimide (PI) PolyPropylene (PP) Polyurethane (PU) Polyvinyl Chloride (PVC) | N/A Poly (Methyl Methacrylate (PMMA)) Polyethylene Terephthalate (PET) Polystyrene (PS) | N/A | |||||
Solvent Content | N/A | |||||||||
Chemical Class | N/A | |||||||||
Uncured Appearance | N/A | |||||||||
Soluble in | N/A | |||||||||
Density | N/A | |||||||||
Test Method for Density | N/A | |||||||||
Test Method for Nominal Viscosity | N/A | |||||||||
Shelf Life at Room Temperature (RT) (22 to 25 Degree Celsius (ºC)) Temperature from Date of Manufacture | N/A | |||||||||
Test Method for Durometer Hardness | N/A | |||||||||
Test Method for Tensile at Break | N/A | |||||||||
Elongation at Break | N/A | |||||||||
Test Method for Elongation at Break | N/A | |||||||||
Test Method for Modulus of Elasticity | N/A | |||||||||
Refractive Index at 20 Degree Celsius (ºC) Temperature | N/A | |||||||||
Test Method for Refractive Index at 20 Degree Celsius (ºC) Temperature | N/A | |||||||||
Boiling Water Absorption (2 Hours (h)) | N/A | |||||||||
Test Method for Boiling Water Absorption (2 Hours (h)) | N/A | |||||||||
Water Absorption (25 Degree Celsius (ºC) Temperature, 24 Hours (h)) | N/A | |||||||||
Test Method for Water Absorption (25 Degree Celsius (ºC) Temperature, 24 Hours (h)) | N/A | |||||||||
Linear Shrinkage | N/A | |||||||||
Test Method for Linear Shrinkage | N/A | |||||||||
Glass Transition Temperature (Tg) | N/A | |||||||||
Test Method for Glass Transition Temperature (Tg) | N/A | |||||||||
Coefficient of Thermal Expansion (CTEα1) | N/A | |||||||||
Test Method for Coefficient of Thermal Expansion (CTEα1) | N/A | |||||||||
Coefficient of Thermal Expansion (CTEα2) | N/A | |||||||||
Test Method for Coefficient of Thermal Expansion (CTEα2) | N/A | |||||||||
Biocompatibility | N/A | |||||||||
Applications | N/A | |||||||||
Features | N/A | |||||||||
Additional Information |
N/A
Dymax® MD® Adhesives, specially formulated for disposable medical device assembly, are used in a wide range of applications including catheter, syringe, anesthesia mask, reservoir, tube set, and medical electronics assembly. They help optimize assembly speeds to enable faster processing, greater output, and lower processing costs while allowing for 100% in-line inspection of bond lines. All of our adhesives are no solvents added and meet both USP Class VI and ISO 10993 biocompatibility standards. MD® adhesives are intended for use in short-term (<29 days) or single-use disposable-device applications only. Dymax® does not authorize their use in long-term implant applications. In all cases, it's the user's responsibility to determine and validate the suitability of these adhesives in the intended medical device. Compatible sterilization methods include gamma irradiation and ethylene oxide. Sterilization by autoclaving may be limited to certain applications. It remains the user's obligation to ascertain the effect of sterilization on the cured adhesive. |
|||||||||
Note | N/A Individual Product Data Sheets (PDS) list complete test data, with copies of test reports available upon request. | N/A Individual Product Data Sheets (PDS) list complete test data, with copies of test reports available upon request. | N/A Individual Product Data Sheets (PDS) list complete test data, with copies of test reports available upon request. |
N/A
See-Cure (Patented Color-Change Technology) Individual Product Data Sheets (PDS) list complete test data, with copies of test reports available upon request. |
N/A
Ultra-Red® (Patented Fluorescing Technology) (UR) See-Cure (Patented Color-Change Technology) Individual Product Data Sheets (PDS) list complete test data, with copies of test reports available upon request. |
|||||
Shelf Life at 1 to 5 Degree Celsius (ºC) Temperature from Date of Manufacture | N/A | |||||||||
Durometer Hardness | N/A | |||||||||
Glass Transition (Tg) | N/A | |||||||||
Test Method for Glass Transition (Tg) | N/A | |||||||||
Recommended Curing Equipment | N/A | |||||||||
Features and Benefits | N/A | |||||||||
|