| Items |
/Asset/Electronic-Encapsulants.jpg 9008 45 Megapascal (MPa) Modulus of Elasticity Electronic Encapsulant |
/Asset/Electronic-Encapsulants.jpg 9101 17.5 Megapascal (MPa) Modulus of Elasticity Electronic Encapsulant |
/Asset/Electronic-Encapsulants.jpg 9102 18.4 Megapascal (MPa) Modulus of Elasticity Electronic Encapsulant |
/Asset/Electronic-Encapsulants.jpg 9103 17.6 Megapascal (MPa) Modulus of Elasticity Electronic Encapsulant |
/Asset/Electronic-Encapsulants.jpg 9001-E V3.1 4,500 Centipoise (cP) Nominal Viscosity Electronic Encapsulant |
|||||
| Description |
N/A
Electronic encapsulants provide complete protection of printed circuit board components and circuitry. The formulations cure tack-free in seconds upon exposure to UV/Visible/LED light. Some products feature secondary heat-cure or ambient moisture-cure capability for shadow areas on PCBAs. They fixture to rigid and flexible PCB platforms used in bare die, wire bond, chip-on-board, and IC applications.
|
|||||||||
| Brands | N/A Dymax® | |||||||||
| Solvent Content | N/A | |||||||||
| Chemical Class | N/A | |||||||||
| Uncured Appearance | N/A | |||||||||
| Soluble in | N/A | |||||||||
| Density | N/A | |||||||||
| Test Method for Density | N/A | |||||||||
| Nominal Viscosity | N/A 4,500 cP | N/A 7,000 cP | N/A 17,000 cP | N/A 25,000 cP | N/A 4,500 cP | |||||
| Test Method for Nominal Viscosity at 20 Revolutions Per Minute (rpm) Speed | N/A | |||||||||
| Shelf Life at Room Temperature (RT) (22 to 25 Degree Celsius (ºC)) Temperature from Date of Manufacture | N/A | |||||||||
| Durometer Hardness | N/A A85 | N/A D30-D50 | N/A D30-D50 | N/A D30-D50 | N/A D45 | |||||
| Test Method for Durometer Hardness | N/A | |||||||||
| Tensile at Break | N/A | |||||||||
| Test Method for Tensile at Break | N/A | |||||||||
| Elongation at Break | N/A 300 % | N/A 38 % | N/A 34 % | N/A 36 % | N/A | |||||
| Test Method for Elongation at Break | N/A | |||||||||
| Modulus of Elasticity | N/A 45 MPa6,500 psi | N/A 17.5 MPa2,550 psi | N/A 18.4 MPa2,670 psi | N/A 17.6 MPa2,560 psi | N/A | |||||
| Test Method for Modulus of Elasticity | N/A | |||||||||
| Glass Transition Temperature (Tg) | N/A | |||||||||
| Test Method for Glass Transition Temperature (Tg) | N/A | |||||||||
| Coefficient of Thermal Expansion (CTEα1) | N/A | |||||||||
| Test Method for Coefficient of Thermal Expansion (CTEα1) | N/A | |||||||||
| Coefficient of Thermal Expansion (CTEα2) | N/A | |||||||||
| Test Method for Coefficient of Thermal Expansion (CTEα2) | N/A | |||||||||
| Refractive Index at 20 Degree Celsius (ºC) Temperature | N/A | |||||||||
| Test Method for Refractive Index at 20 Degree Celsius (ºC) Temperature | N/A | |||||||||
| Boiling Water Absorption (2 Hours (h)) | N/A | |||||||||
| Test Method for Boiling Water Absorption (2 Hours (h)) | N/A | |||||||||
| Water Absorption (25 Degree Celsius (ºC) Temperature, 24 Hours (h)) | N/A | |||||||||
| Test Method for Water Absorption (25 Degree Celsius (ºC) Temperature, 24 Hours (h)) | N/A | |||||||||
| Linear Shrinkage | N/A | |||||||||
| Test Method for Linear Shrinkage | N/A | |||||||||
| Dielectric Constant at 1 Megahertz (MHz) Frequency | N/A | |||||||||
| Test Method for Dielectric Constant at 1 Megahertz (MHz) Frequency | N/A | |||||||||
| Dissipation Factor at 1 Megahertz (MHz) Frequency | N/A | |||||||||
| Test Method for Dissipation Factor at 1 Megahertz (MHz) Frequency | N/A | |||||||||
| Dielectric Breakdown Voltage | N/A | |||||||||
| Test Method for Dielectric Breakdown Voltage | N/A | |||||||||
| Volume Resistivity | N/A | |||||||||
| Test Method for Volume Resistivity | N/A | |||||||||
| Surface Resistivity | N/A | |||||||||
| Test Method for Surface Resistivity | N/A | |||||||||
| Recommended Dispense Equipment | N/A | |||||||||
| Recommended Curing Equipment | N/A | |||||||||
| Recommended Substrates | N/A | N/A | N/A | N/A | N/A Acrylonitrile Butadiene Styrene (ABS) Flame Retardant (FR-4) Metal Polycarbonate (PC) Polyvinyl chloride (PVC) | |||||
| Recommended Adhesives | N/A | |||||||||
| Halogen Free? | N/A Yes | |||||||||
| Cured Linear Shrinkage | N/A | |||||||||
| Cured Durometer Hardness | N/A | |||||||||
| Ultraviolet (UV) Cure Speed | N/A | N/A | N/A | N/A | N/A 15 seconds | |||||
| Ultraviolet (UV) Cure Depth | N/A | N/A | N/A | N/A | N/A 6.4 mm0.25 in | |||||
| Note for Ultraviolet (UV) Cure Speed and Depth | N/A | N/A | N/A | N/A | N/A UV cure speed depends on the intensity reaching the surface of the resin. Cure speed was measured at an intensity of 175 mW/cm2. | |||||
| Applications |
N/A
|
N/A
|
N/A
|
N/A
|
N/A Potting Sealing | |||||
| Features | N/A | |||||||||
| Additional Key Features |
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
|||||
| Additional Information | N/A | |||||||||
|
|
||||||||||